Table 10-1Numeric Codes and Text Messages (continued)

Control panel message

Description

Recommended action

 

 

 

 

 

 

3.

If the memory configuration was recently

 

 

 

changed, unplug the power cord, restore

 

 

 

the original memory configuration, and

 

 

 

reboot the computer.

 

 

4.

If the error persists, replace the system

 

 

 

board.

 

 

 

 

2202-PMM Deallocation Error during MEBx

Memory error during POST execution of the

1.

Reboot the computer.

cleanup

Management Engine (ME) BIOS Extensions

2.

Unplug the power cord, re-seat the

 

option ROM.

 

 

memory modules, and reboot the

 

 

 

 

 

 

computer.

 

 

3.

If the memory configuration was recently

 

 

 

changed, unplug the power cord, restore

 

 

 

the original memory configuration, and

 

 

 

reboot the computer.

 

 

4.

If the error persists, replace the system

 

 

 

board.

 

 

 

 

2203-Setup error during MEBx execution

MEBx selection or exit resulted in a setup

1.

Reboot the computer.

 

failure.

2.

Unplug the power cord, re-seat the

 

 

 

 

 

memory modules, and reboot the

 

 

 

computer.

 

 

3.

If the memory configuration was recently

 

 

 

changed, unplug the power cord, restore

 

 

 

the original memory configuration, and

 

 

 

reboot the computer.

 

 

4.

If the error persists, replace the system

 

 

 

board.

 

 

 

 

2204-Inventory error during MEBx execution

BIOS information passed to the MEBx resulted

1.

Reboot the computer.

 

in a failure.

2.

If the error persists, update to the latest

 

 

 

 

 

BIOS version.

 

 

3.

If the error still persists, replace the

 

 

 

system board.

 

 

 

 

2205-Interface error during MEBx execution

MEBx operation experienced a hardware error

1.

Reboot the computer.

 

during communication with ME.

2.

If the error persists, update to the latest

 

 

 

 

 

BIOS version.

 

 

3.

If the error still persists, replace the

 

 

 

system board.

 

 

 

2211-Memory not configured correctly for

DIMM1 or XMM1 is not installed.

Make sure there is a memory module in the

proper MEBx execution.

 

black DIMM1 socket and that it is properly

 

 

seated.

 

 

 

 

2212-USB Key Provisioning failure writing to

USB device used for USB key provisioning will

1.

Try a different USB key device for

device

not allow BIOS to update provision file

 

provisioning.

 

properly.

2.

If the error persists, update to the latest

 

 

 

 

 

BIOS version and ME firmware version.

 

 

3.

If the error still persists, replace the

 

 

 

system board.

 

 

 

 

104 Chapter 10 POST Error Messages