40CHAPTER 4: SOFTWARE MAINTENANCE
Booting from Flash
Entering serial port sub-menu 
Enter <2> in Boot main menu and the system will enter serial port 
Boot From Serial Port
======================<SERIAL 
<2> Download To Flash
<3> Change Boot Parameter <4> Exit To Main Menu
===============================================================
Enter your 
1Downloading via serial port application files to memory and starting them.
Enter <1> in serial port 
2Downloading to Flash
Enter <2> in serial port 
3Modifying serial port parameters
Enter <3> in serial port 
| ========================<BAUDRATE SET>======================= | 
 | |
| Note: Change The HyperTerminal's Baudrate Accordingly. | 
 | |
| <1> 9600(Default) | 
 | |
| <2> 19200 | 
 | |
| <3> 38400 | 
 | |
| <4> 57600 | 
 | |
| <5> 115200 | 
 | |
===============================================================
Enter Your 
The information indicates you to choose desired baudrate. By default, the baudrate is 9600 bps. Select a target item and press <Enter>. When you select <5>, the system prompts
Enter your 
Change The BaudRate On PC Side First!
Change baudrate of the configuration PC as per the prompts. Disconnect the system and resume dialup, to make the new parameter take effect. See Modifying serial port parameters, for more details.
4Returning to Boot main menu
5Enter <4> in serial port 