16 CHAPTER 1: INTRODUCING THE ROUTER 6000 FAMILY

AUX interface

Table 6 AUX interface attributes

Attribute

Description

 

 

Connector

RJ45

Interface standard

RS232

Baud rate

300 ~ 115200bps

Supported service

Modem dialup

Backup

 

 

 

Ethernet interface

The RPU provides two 10/100Base-TX Ethernet ports on its panel (Ethernet 0/0/0 at left and Ethernet 0/0/1 at right). Their attributes are listed in the following table.

Table 7 Ethernet interface attributes

Attribute

Description

 

 

Connector

RJ45

Interface type

MDI

Supported frame format

Ethernet_II

Ethernet_SNAP

Operating mode

10M/100Mbps auto-sensing

Full duplex/Half-duplex

 

 

Power Modules The power modules of 3Com 6000 Routers can work in either single-power or dual-power mode. In dual-power mode, the two Power Modules function in a redundant loading sharing mode. The input interruption or failure of a PWR does not affect the operation of another PWR, and this operating PWR will provide all the power required by the system.

Power Modules control functions of overcurrent protection and overvoltage protection.You can connect the PWR to the backplane by inserting it from the rear of router chassis. It is hot swappable and its switchover will not affect the ongoing system operation.

If you want to install a 6000 Router in a communication equipment room, you should make sure that the power distribution cabinet can provide the lightning protection box or arrester against the current of 20KA and above.

Page 16