5

HARDWARE MAINTENANCE

Hardware

Please review the following cautions before installation or maintenance:

Maintenance

On a mounting screw of 3Com 6000 series router chassis, there is an

 

 

anti-dismantle seal of 3Com Corporation. The seal must be kept intact

 

before the support agent performs maintenance on the switch.

 

Remember to wear ESD-preventive wrist strap.

 

 

Power Module

6000 Series Routers support 1+1 redundant power system. The power modules

Removal and

are hot-swappable.

Installation

 

Remove a Power

Module

1Turn off power switch.

2Remove the power cord connected to the power module to be removed and loosen the two captive screws in the top panel of the module.

3Hold the handle of the module and gently pull the module out along the guides.

Figure 1 Power Module Removal

Install a Power Module

1Hold the handle of the power module panel, slowly push the module into the chassis along the guides until it touches the rear power panel inside the power slot of the chassis.

2Fasten the two captive screws in the power module panel.