Time Protocols

TimeP: Viewing, Selecting, and Configuring

Menu: Viewing and Configuring TimeP

To View, Enable, and Modify the TimeP Protocol:

1.From the Main Menu, select:

2.Switch Configuration...

1.System Information

==========================- CONSOLE - MANAGER MODE -==========================

Switch Configuration - System Information

System Name : ProCurve

System Contact :

System Location :

Inactivity Timeout (min) [0] : 0

MAC Age Time (sec) [300] : 300

Inbound Telnet Enabled [Yes] : Yes

Web Agent Enabled [Yes] : Yes

Time Sync Method [None] : TIMEP

 

 

 

 

TimeP Mode [Disabled] : Disabled

 

Time Protocol Selection Parameter

 

Tftp-enable [Yes] : Yes

 

TIMEP (the default)

 

Time Zone [0] : 0

 

SNTP

 

Daylight Time Rule [None] : None

 

None

 

Actions-> Cancel Edit Save Help

Figure 9-12. The System Information Screen (Default Values)

Press [E] (for Edit). The cursor moves to the System Name field.

2.Use [v] to move the cursor to the Time Sync Method field.

3.If TIMEP is not already selected, use the Space bar to select TIMEP, then press [v] once to display and move to the TimeP Mode field.

4.Do one of the following:

Use the Space bar to select the DHCP mode, then press [v] to move the cursor to the Poll Interval field, and go to step 6.

Use the Space bar to select the Manual mode.

i. Press [>] to move the cursor to the Server Address field.

9-17