Interface Access and System Information

 

Interface Access: Console/Serial Link, Web, and Inbound Telnet

 

 

N o t e

If you change the Baud Rate or Flow Control settings for the switch, you

 

should make the corresponding changes in your console access device. Oth-

 

erwise, you may lose connectivity between the switch and your terminal

 

emulator due to differences between the terminal and switch settings for these

 

two parameters.

 

All console parameter changes except events and inactivity-timerrequire that

 

you save the configuration with write memory and then execute boot before the

 

new console configuration will take effect.

 

 

For example, to use one command to configure the switch with the following:

■VT100 operation

■19,200 baud

■No flow control

■10-minute inactivity time

■Critical log events

you would use the following command sequence:

The switch implements the Event Log change immediately. The switch implements the other console changes after executing write memory and reload.

Figure 7-4. Example of Executing the Console Command with Multiple Parameters

7-9