Troubleshooting

Debug/Syslog Operation

The CLI command is:

Syntax: logging <ip-addr> control-descr <text_string>]

no logging <ip-addr> [control-descr]

 

 

An optional user-friendly description that can be associated with

 

 

a server IP address. If no description is entered, this is blank. If

 

 

<text_string> contains white space, use quotes around the string.

 

 

IPv4 addresses only. Use the no form of the command to remove

 

 

the description.

 

 

Limit: 255 characters

 

 

Note: To remove the description using SNMP, set the description

 

 

to an empty string.

 

 

 

 

 

ProCurve(config)# logging 10.10.10.2 control-descr syslog_one

 

 

 

 

 

Figure C-9. Example of the Logging Command with a Control Description

 

 

 

C a u t i o n

 

Entering the no logging command removes ALL the syslog server addresses

 

 

without a verification prompt.

 

 

Adding a Priority Description

 

 

 

 

You can add a user-friendly description for the set of syslog filter parameters

 

 

using the priority-descroption. The description can be added with the CLI or

 

 

SNMP. The CLI command is:

 

 

Syntax: logging priority-descr <text_string>

 

 

no logging priority-descr

 

 

Provides a user-friendly description for the combined filter

 

 

values of severity and system module. If no description is

 

 

entered, this is blank. If <text_string> contains white space,

 

 

use quotes around the string. Use the no form of the command

 

 

to remove the description.

 

 

Limit: 255 characters

C-52