Interface Access and System Information

System Information

System InformationSystem Information Features

Feature

Default

Menu

CLI

Web

 

 

 

 

 

System Name

switch product

page

page

page

 

name

7-13

7-15

7-19

System Contact

n/a

page

page

page

 

 

7-13

7-15

7-19

System Location

n/a

page

page

page

 

 

7-13

7-15

7-19

MAC Age Time

300 seconds

page

page

 

 

7-13

7-17

 

Time Sync Method

None

See Chapter 9, “Time Protocols”.

Time Zone

0

page

page

 

 

7-13

7-18

 

Daylight Time Rule

None

page

page

 

 

7-13

7-18

 

Time

January 1, 1990 at

page

 

00:00:00 at last

 

7-18

 

 

power reset

 

 

 

 

 

 

 

 

Configuring system information is optional, but recommended.

System Name: Using a unique name helps you to identify individual devices where you are using an SNMP network management tool such as ProCurve Manager.

System Contact and Location: This information is helpful for identifying the person administratively responsible for the switch and for identifying the locations of individual switches.

MAC Age Time: The number of seconds a MAC address the switch has learned remains in the switch’s address table before being aged out (deleted). Aging out occurs when there has been no traffic from the device belonging to that MAC address for the configured interval.

Time Sync Method: Selects the method (TimeP or SNTP) the switch will use for time synchronization. For more on this topic, refer to Chapter 9, “Time Protocols”.

7-12