Interface Access and System Information

System Information

Listing the System Enclosure Information. This command lists the sys-

tem enclosure information.

Syntax: show system enclosure

This example shows the switch’s enclosure configuration.

ProCurve# show system enclosure

Rack and Enclosure Information

Rack Name

: Donner_Bldg5U

Rack Unique ID

: Default RUID

Enclosure Name

: 2XX81401UP

Enclosure Serial Number

: 2XX81401UP

Figure 7-9. Example of CLI System Enclosure Information ListingConfigure a System Name, Contact, and Location for the Switch. To

help distinguish one switch from another, configure a plain-language identity for the switch.

Syntax: hostname < name-string>

snmp-server [contact <system-contact>] [location <system-location>]

Each field allows up to 255 characters.

For example, to name the switch “Blue” with “Next-4474” as the system contact, and “North-Data-Room” as the location:

7-15