MODEL 8559A

ADJUSTMENTS

ADJUSTMENTS

5-19. LOG AMPLIFIER LOG AND LINEAR ADJUSTMENTS

REFERENCE:

A14 and A15 Schematics

DESCRIPTION:

Step attenuators are used to change the level of the input signal to the spectrum analyzer in calibrated steps. The output of Vertical Driver and Blanking Assembly A15 is monitored, and adjustments are performed to calibrate Log Amplifier Assembly A14.

 

 

 

 

 

SIGNAL QENERATOR

 

D l Q l T A L VOLTMETER

 

 

 

 

 

1 CABLE

 

RF OUTPUT I

 

 

 

 

ADAPTER

D l SPLAY

 

 

ASSEMBLY

 

 

 

 

ADAPTER

 

 

 

 

 

 

 

 

STEP

 

 

 

 

ATTENUATORS

ADAPTER 65 1

 

A t O W l

 

EXTENDER

- ' O Z ~ ~ SPECTRUM

 

CABLE

 

 

@@@ IANALYZER

 

FIGURE53. LOG AMPLIFIER LOG AND LINEAR ADJUSTMENTSTESTSETUP

 

EQUIPMENT:

 

 

Signal Generator

.........................................................

H P 8640B

Digital Voltmeter

........................................................

HP 3456A

Step Attenuator (10-dB/step) ......................................

HP 355D, Opt. H82

Step Attenuator (1-dB/step) .......................................

H P 355C, Opt. H80

Cable Assembly, Banana Plug to BNC (m) ...................................

HP 1-1001A

Adapter, Type N (m) to BNC (f) .........................................

HP 1250-0780

Adapter, SMC (m) to BNC (f) ...........................................

HP 1250-0832

Extender Cable Assembly ..............................................

HP 5060-0303