MODEL8559A

PERFORMANCETESTS

 

PERFORMANCE TESTS

4-26. DISPLAY FIDELITY (Cont'd)

 

FREQ SPAN/DIV .........................................................

500 kHz

RESOLUTION BW ..............................................

300 kHz, uncoupled

INPUT ATTEN .............................................................

10 dB

REFERENCE LEVEL .......................................................

0 dBm

REFLEVELFINE ..............................................................

0

Amplitudescale ..............................................................

LIN

SWEEP TIME/DIV ........................................................

AUTO

SWEEPTRIGGER .....................................................

FREERUN

ALTIF .....................................................................

OFF

SIC IDENT .................................................................

OFF

BL CLIP ....................................................................

OFF

VIDEO FILTER .............................................................

OFF

Digital Voltmeter:

 

RANGE .....................................................................

100

FUNCTION ...............................................................

v P C )

AUTO CAL ...............................................................

AUTO

TRIGGER ............................................................

INTERNAL

MATH .....................................................................

OFF

Signal Generator:

 

COUNTERMODE ...........................................................

INT

AM ........................................................................

OFF

FM ........................................................................

OFF

FREQUENCYTUNE ......................................................

30MHz

RF ..........................................................................

ON

OUTPUT LEVEL ..........................................................

0 dBm

2.With no signal at spectrum analyzer's INPUT 5052, measure and record offset voltage at (AUX A) VERTI- CAL OUTPUT connector.

3.Connect equipment as shown in Figure 4-22. Set step attenuator to 0 dB.

4.Set spectrum analyzer's Amplitude Scale to 10 dB/DIV and adjust TUNING control to center signal on CRT display.

5.Set spectrum analyzer's FREQ SPAN/DIV control to zero (0), VIDEO FILTER full CW (not in detent), and RESOLUTION BW control to 1 MHz. Adjust TUNING control for maximum reading on DVM.

6.Set signal generator OUTPUT LEVEL control for DVM reading of (+ 800 mV + offset (step 2) f0.5 mV). Trace should be approximately at top CRT graticule line.

7.Record DVM readings for step attenuator settings, from 0 dB through 70 dB, in Table 4-16.