HP J4367A, A6584A, A1354A, A1353A manual Event notification messages do not appear on console screen

Models: A6584A

1 120
Download 120 pages 46.74 Kb
Page 90
Image 90

Test

LED flash error code

Description

 

 

 

1

Permanently on

DRAM failure

 

 

 

2

2 flashes

DMA Mem to Mem error

 

 

 

3

3 flashes

IRQ error

 

 

 

4

4 flashes

Ethernet error

 

 

 

5

5 flashes

Serial loop back error

 

 

 

6

6 flashes

RTC error

 

 

 

Event notification messages do not appear on console screen

Action: If you are using SLES 9, upgrade the KDE or use a different desktop, such as GNOME.

Event notifications are not being sent

Action: While email and SNMP trap notifications must be set up on their respective screens, notifications must also be enabled per event on the Event Notifications screen ("Event Notifications menu" on page 64).

FTP error messages appear when connecting through Linux

Symptom: When connecting to FTP through Linux, error messages about bad commands appear.

Action: The user can log in although the error messages appear.

Flash update fails over a serial connection

Action: Disable any serial port being configured during the flash update, such as iLO, or use an FTP connection.

HP SIM lists a discovered UPS as Unmanaged in the System Type column

Action:

1.Delete the discovered UPS from HP SIM.

2.Using the management module web interface, add the HP SIM server as a Manager on the SNMP Managers tab (on page 62).

3.Rediscover the UPS in HP SIM.

Troubleshooting 90