HP D6028-90004 manual Self Test Power Up Sequence

Models: D6028-90004

1 114
Download 114 pages 12.75 Kb
Page 28
Image 28

Chapter 3

Hardware Installation and Configuration

Self Test Power Up Sequence

During the HP TopTools Remote Control card’s self test, observe the diagnostic LEDs located just above the card’s RS-232 port (refer to Figure 3-6).

1.The green (heartbeat) LED and the red (error) LED switch on for about 10 seconds.

2.If no errors are detected, the green heartbeat LED flashes every 5 seconds, indicating normal operation. After initial power-up, the red LED should not be visible.

3.If, after power up, the red error LED switches on, a problem with the HP Remote Control card is indicated. Refer to Appendix F for detailed information about blinking LED failure codes.

Before you can use HP TopTools Remote Control, an independent communications link (LAN or modem) must be set up, cabled, and properly configured. Proceed to the next chapter for detailed instructions on how to set up a remote connection to the HP TopTools Remote Control card.