A Event Codes
The table below describes the event codes that can be listed in the event log and optionally directed to specified users via
In the Severity column, an asterisk (*) indicates that the severity rating depends on particular data for the event. The final column indicates which NOS agents need to be loaded on the HP NetServer before the particular event is generated. Refer to the HP NetServer SNMP agents documentation (viewable in HP Information Assistant on the NetServer Documentation CD) for agent installation and configuration instructions.
NOTE | It’s a good idea to copy appropriate sections of this table and |
| keep it with the pager you use to receive notifications. A |
| regularly updated list of HP supported event codes is available |
| via the WWW at http://www.hp.com/go/netserver. |
|
|
Notification and log messages are limited to a length of 40 characters.
Event |
|
|
|
Code | Severity | Description | Agent |
|
| System Power |
|
00201 | * | Voltage +5V Threshold | None |
00202 | * | Voltage | None |
00203 | * | Voltage +12V Threshold | None |
00204 | * | Voltage | None |
00206 | * | Voltage +3.3V Threshold | None |
00207 | Warning | SCSI Terminator Voltage Limit Exceeded | None |
00210 | * | Primary CPU Voltage Threshold | None |
00211 | * | Secondary CPU Voltage Threshold | None |
00800 | * | Redundant Power Supply Removed or Inserted | None |
00801 | Warning | Redundant Power Supply Aux or DC Power Failure | None |
00900 | Informational | Redundant Power Supply Unit Redundancy Gained | None |
57