Replace the separation pad

Normal use with good media causes wear. The use of poor media might require more frequent replacement of the separation pad.

If the product regularly pulls multiple sheets of media at a time, you might need to change the separation pad.

NOTE: Before you change the separation pad, clean the pickup roller. See Clean the pickup roller on page 61.

WARNING! Before changing the separation pad, turn the product off, disconnect the power cord from the wall outlet, and then wait for the product to cool.

1.Disconnect the product power cord from the product.

2.Remove the paper and close the input tray. Set the product on its front.

3.At the bottom of the product, unscrew the two screws holding the separation pad in place.

58 Chapter 7 Manage and maintain the product

ENWW