ES-IS Init Option
When switched on, the router sends a directed IS Hello to a new
ES neighbor.
IS-IS Authentication
If switched on, each IS-IS packet includes the transmit password
configured for the domain, area, and circuits. Also, no checking
against receive passwords is done.
timers Configures the OSI timers, excluding any circuit timers.
Example:
set timers
Complete SNP [10 sec]:
Partial SNP [2 sec]:
Minimum LSP Generation [30 sec]:
Maximum LSP Generation [900 sec]:
Minimum LSP Transmission [5 sec]:
Minimum Broadcast LSP Transmission [33 msec]:
Waiting Time [60 sec]:
Designated Router ISIS Hello [1 sec]:
Suggested ES Configuration Timer (sec) [10]:
Complete SNP
Selects the interval between the generation of complete sequence
number PDUs (SNP) by the designated router on a broadcast
circuit.
Partial SNP
Selects the minimum interval between sending partial sequence
number PDUs (SNP).
Minimum LSP Generation
Selects the minimum interval between successive generations of
Link State Packets (LSPs) with the same LSP ID generated by the
router.
Maximum LSP Generation
Selects the maximum interval between LSPs generated by the
router.
Minimum LSP Transmission
Selects the minimum interval between retransmissions of a LSP.
Minimum Broadcast LSP Transmission
Selects the minimum transmission, in milliseconds, between
transmission of LSPs on a broadcast circuit.
Waiting Time
Selects the number of seconds the update process should delay in
the waiting state before entering the ON state.
Designated Router ISIS Hello
Selects the interval between the generation of IS-IS hello PDUs by
the router if the router is the designated router on a LAN.
Suggested ES Configuration Timer
Sets the option field of the IS hello message that instructs the ES to
change the rate at which it sends ES hellos.
transmit-password
Sets or changes a transmit password.
Example:
DECnet V/OSI Configuration Commands (Talk6)
328 MRS V3.2 Protocol Config Ref Vol2