Example:
list timers Timers:
Complete SNP (sec) = 10 Partial SNP (sec) = 2
Min LSP Gen (sec) = 30 Max LSP Gen (sec) = 900
Min LSP Xmt (sec) = 30 Min Br LSP Xmt (msec) = 33
Waiting Time (sec) = 60 DR ISIS Hello (sec) = 1
ES Config Timer (sec) = 10
Timers:Indicates the configuration of the OSI timers excluding any per
circuit timers.
Complete SNP
The interval between generation of complete SNPs.
Partial SNP
The minimum interval between sending partial SNPs.
Min LSP Generation/Max LSP Generation
The minimum and maximum intervals between generations of
LSPs.
Min LSP Transmission
The minimum interval between LSP retransmissions.
Min Broadcast LSP Transmission
The minimum interval between LSP retransmissions on a broadcast
circuit.
Waiting Time
The time the update process must delay before entering the ON
state.
DR ISIS Hello
The interval between generations of IS-IS hello PDUs if this router
is a designated router.
ES Config Timer
The minimum interval between that an ES must send a hello packet
each time an interface comes up.
virtual-circuits
Displays information about all X.25 virtual circuits.
Example: list virtual-circuits
Set
Use the set command to configure the router to run the OSI protocol.
Syntax:
set adjacency
algorithm
globals
network-entity-title
phaseivpfx
subnet
switches
DECnet V/OSI Configuration Commands (Talk 6)
Chapter10. Configuring and Monitoring OSI/DECnet V 323