Environmental Conditions
8Environmental Conditions
The VRM/EVRD design, including materials, should meet the environmental requirements specified below.
8.1Operating Temperature - PROPOSED
The VRM/EVRD shall meet all electrical requirements when operated at the Thermal Design Current (IccTDC) over an ambient temperature range of 0ºC to +45ºC with a minimum airflow of 400 LFM (2 m/s). The volumetric airflow (Q) can be measured through a wind tunnel. For testing, the baseboard should be mounted in a duct. (A VRM should be mounted on a PCB, and then mounted in a duct.) The recommended duct
•Y direction duct width (perpendicular to flow, horizontal) = 0.3 m
•Z direction duct height (perpendicular to flow, vertical) = 0.15 m
•Minimum X direction duct length in front of VRM = 6 hydraulic diameters = 1.2 m
•Minimum X direction duct length behind VRM = 2 hydraulic diameters = 0.4 m
•Velocity (v) is calculated from the volumetric flow and
•v = Q/(0.3 x 0.15)m2 Operating conditions shall be considered to include 10 cycles between min and max temperature at a rate of 10ºC/hour and a dwell time of 30 minutes at extremes. Temperature and airflow measurements should be made in close proximity to the VRM.
8.2VRM Board Temperature - REQUIRED
To maintain the connector within its operating temperature range, the VRM board temperature, at the connector interface, shall not exceed a temperature equal to 90ºC. At no time during the operation is the board permitted to exceed 90ºC within a distance of 2.54 mm [0.100”] from the top of connector (0.4 in. from board edge). In order not to exceed 90ºC, it is recommended that the board be constructed from
8.3Non-Operating Temperature - PROPOSED
The VRM/EVRD shall not be damaged when exposed to temperatures between
8.4Humidity - PROPOSED
85% relative – operating
95% relative –
45 |