SECTION 4 " Configuration

[Values]

Use [Values] to enter pattern lists that contain byte patterns that match consecutive bytes in received Ethernet frames. Settings for [Values] are referenced by the Value Id from the Expression Table. The values to be used in a filter expression are as follows:

Value Id

Value

10

20

30

.

.

.

220

Filter expression values have the following settings:

Value Id

0

Value

 

 

 

Setting

Description

Value Id

An identifier used by an expression in the Expres-

 

sion Table. The range is 0 (default) to 255. All

 

values with the same identifier are considered to

 

be in the same list. When used in an expression

 

that allows only one value (that is, LT, LE, GE, or

 

GT), only the first value in the list is used.

Value

One of the values to be compared. The range is 8

 

hexadecimal pairs.

4-566710 Access Point User’s Guide