SECTION 5 " Software Download

"You have established a connection between a PC and the access point’s DIAG port, and have accessed the ROM command monitor.

"An old version of FLASH is in segment 1.

"The new version of FLASH is going into segment 1.

"Segment 2 is the active boot segment.

1.When the access point has entered the ROM command monitor, type the following commands to upgrade the unit.

Command

Description

ap>pwd

Enter the password menu.

Enter the password.

The default password is

 

CR52401OWL (must be upper-

 

case).

passwd>fe 1

Erase FLASH segment 1.

passwd>x

Exit the password menu.

ap>fx 1

Download the new FLASH file into

 

segment 1.

passwd>fb 1

Change the boot segment number

 

from 2 (in this example, the active

 

boot segment) to 1.

ap>fr

Run the new FLASH boot file by

 

restarting the access point.

2.After the access point reboots and is running in FLASH mode, use the Fd command to display the file directory and verify that the new version of FLASH is in segment 1.

3.Ensure that this access point has a valid IP address. Change the address if necessary and remember what it is. You need the IP address to configure TFTP clients in other access points.