Intermec 6710 manual Status Mode, Error Status

Models: 6710

1 348
Download 348 pages 28.47 Kb
Page 195
Image 195

SECTION 6 " Indicator Lights

STATUS

The STATUS (left) light indicates the access point’s operating status. When the light is OFF, the access point is operating normally. When the light is ON, it is in error mode.

"NOTE: In certain cases the following text refers to the indicator lights by number. Lights are numbered from left to right. Light 1 is labeled LINK and Light 8 is labeled NIC2.

The access point enters error mode when it detects a malfunction during the power-on self tests or when certain hardware malfunctions occur during normal operation. When the STATUS light is ON to indicate the error mode, indicator lights 4 through 8 (the STATUS MODE light and the NETWORK and PCMCIA light pairs) display a binary error status code between 1 and 31. This code indicates the specific condition causing the error status as shown in Table 6-2. Descriptions of errors are on page 6-4.

Table 6-2

Error Mode Status Codes

Status

Mode

R-LINK

W-LINK

NIC1

NIC2

Error Status

ON

OFF

OFF

OFF

OFF

ON

Hardware error 1.

ON

OFF

OFF

OFF

ON

OFF

Hardware error 2.

ON

OFF

OFF

OFF

ON

ON

Hardware error 3.

ON

OFF

OFF

ON

OFF

OFF

Internal serial loop-

 

 

 

 

 

 

back test failed.

ON

OFF

OFF

ON

OFF

ON

Internal MACE AUI

 

 

 

 

 

 

loopback test failed.

ON

OFF

OFF

ON

ON

OFF

Internal 10BASE-T

 

 

 

 

 

 

loopback test failed.

ON

OFF

OFF

ON

ON

ON

Timer test failed.

6710 Access Point User’s Guide 6-3

Page 195
Image 195
Intermec 6710 manual Status Mode, Error Status