APPENDIX G " MIB

PSEntry ::=

 

 

SEQUENCE {

 

 

psPort

 

INTEGER,

psIfIndex

 

INTEGER,

psAddress

 

PhysAddress,

psType

 

INTEGER,

psState

 

INTEGER,

psCost

 

INTEGER,

psHelloPeriod

 

INTEGER,

psHelloCount

 

Counter,

psMacdWindow

 

INTEGER,

psMacdQSize

 

Gauge,

psMacdTimeouts

 

Counter,

psIsPrimary

 

INTEGER,

psIsSecondary

 

INTEGER,

psIsSecondaryCandidate

INTEGER,

psSecondaryUniFlooding

INTEGER,

psSecondaryMultiFlooding INTEGER,

psIsRadio

 

INTEGER,

psPendEnabled

 

INTEGER

}

 

 

psPort

OBJECT-TYPE

SYNTAX INTEGER (1..4)

 

 

ACCESS read-only

 

 

STATUS mandatory

 

 

DESCRIPTION

 

 

”MAC-R port ID (1-4).

A number which uniquely

identifies the port.”

 

 

::= { psEntry 1 }

 

 

psIfIndex

OBJECT-TYPE

SYNTAX INTEGER

 

 

ACCESS read-only STATUS mandatory

DESCRIPTION

”MAC-D interface index. The index matches the interface index of the associated row in the mib-II interface table.”

::= { psEntry 2 }

psAddressOBJECT-TYPE SYNTAX PhysAddress

ACCESS read-only STATUS mandatory

DESCRIPTION

”802 address of the port” ::= { psEntry 3 }

6710 Access Point User’s Guide G-37

Page 287
Image 287
Intermec 6710 manual Integer