SECTION 3 " Installation

10BASE2 Ethernet

The access point connects to the end or middle of the 10BASE2 cable segment.

"NOTE: Cable lengths between network devices on the 10BASE2 Ethernet LAN must meet ANSI/IEEE standards.

End of Segment

See Figure 3-7 and the procedure following it.

10 BASE 2

10 BASE T

AUI

DIAG

 

AC INPUT

100/240 VAC

1

2

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Cable terminator (50 ohm)

2.T-connector

3.10BASE2 cable

Figure 3-7

End of 10BASE2 Segment

1.Plug the T-connector (2) into the 10 BASE 2 port.

2.Plug one end of the Ethernet cable (3) into an open end of the T-connector. Align the notches in the cable end with the posts on the T-connector, push the cable in, and twist one-quarter turn.

3.Plug the cable terminator (1) into the other end of the T-connector.

6710 Access Point User’s Guide 3-11

Page 55
Image 55
Intermec 6710 manual 10BASE2 Ethernet, End of Segment, See -7 and the procedure following it