SECTION 3 " Installation

1.Inspect where the access point will be mounted and determine what hardware is needed. Different surfaces such as drywall, wood, and concrete block require different mounting hardware. For this reason, a universal mounting bracket is included with the access point.

2.Remove the mounting plate from the bottom of the access point.

3.Using the mounting plate as a template, mark where the anchors that secure the mounting plate to the surface should be located.

4.Attach the access point mounting plate to the wall or ceiling with 2I x 1/4I diameter lag screws or bolts, depending upon the surface. The mounting plate must be secured to the surface by at least four anchors, one on each corner.

5.Reattach the access point to the mounting plate.

6.Make all Ethernet connections. See “Connecting to Ethernet.”

7.Make all power connections. See “Applying Power” on page 3-20.

8.Watch the indicator lights to verify that the access point is working properly. See Section 6, “Indicator Lights,” for help.

"NOTE: An optional locking kit is available. See Section 2, “Features and Functional Overview,” for more information.

Connecting to Ethernet

The following pages show how to connect the access point to 10BASE2, 10BASE5, and 10BASE-T Ethernet.

3-106710 Access Point User’s Guide

Page 54
Image 54
Intermec 6710 manual Connecting to Ethernet