APPENDIX D " S-UHF Specifications and Antennas

"NOTE: A site survey is required for this type of installation.

-105 dBm

Access Point A

Access Point B

Figure D-2

Frequency Reuse

In this type of installation, you can install access points on the same frequency. Each access point can sustain the single frequency wireless station population and transaction rate. The guideline for frequency reuse is:

The signal level produced by access point “A” must be less than --105 dBm at the required coverage limit of access point “B.”

Increasing System Throughput

To increase the wireless station population or system transaction rate, you can overlap access point coverage areas and use multiple frequencies. The system design allows up to four frequencies, 100 stations, and three transactions per second. Large wireless station populations or transaction rates require use of one of the high speed RF media.

D-86710 Access Point User’s Guide

Page 220
Image 220
Intermec 6710 manual Increasing System Throughput, Figure D-2