Intermec 6710 manual Mode, Error Status Description

Models: 6710

1 348
Download 348 pages 28.47 Kb
Page 196
Image 196

SECTION 6 " Indicator Lights

"NOTE: Contact the Customer Response Center for help with the following.

Error Status

Description

Hardware errors 1, 2, and 3

These errors indicate an internal hard- ware error or malfunction. The errors can occur when you apply power to the access point. If it encounters a hardware error, it no longer functions.

Internal serial loop-

This failure occurs if the access point

back test failed

does not successfully complete the

 

power-on self-test. The error indicates a

 

probable hardware malfunction

 

associated with the DIAG port. In most

 

cases, the unit continues to operate nor-

 

mally, but the error condition still exists.

Internal MACE

This failure occurs if the access point

(Media Access Con-

does not successfully complete the

troller for Ethernet)

power-on self-test. The error indicates a

AUI loopback test

probable hardware malfunction

failed

associated with the AUI port. In most

 

cases the unit continues to operate nor-

 

mally, but the error condition still exists.

Internal 10BASE-T

This failure occurs if the access point

loopback test failed

does not successfully complete the

 

power-on self-test. The error indicates a

 

probable hardware malfunction

 

associated with the 10BASE-T port. In

 

most cases the unit continues to operate

 

normally, but the error condition still

 

exists.

Timer test failed

This failure occurs when the access point

 

timer circuit malfunctions. If a timer er-

 

ror occurs, the unit no longer functions.

MODE

The right STATUS light is labeled MODE. It indicates the current status of the access point (Table 6-3).

6-46710 Access Point User’s Guide