APPENDIX G " MIB

bsMyRootPriority OBJECT-TYPE SYNTAX INTEGER (0..7)

ACCESS read-only STATUS mandatory

DESCRIPTION

”Root priority of the AP (0-7). An AP with a root priority of 0 can not become the root node. The AP with the highest priority will become the root in an OWL LAN”

::= { brgState 9 }

bsRootPort

OBJECT-TYPE

SYNTAX INTEGER (1..4)

 

ACCESS read-only STATUS mandatory

DESCRIPTION

”MAC-R root port number. The port number (1-4) of the port used to communicate with the parent node.” ::= { brgState 10 }

bsDesignatedRootAddress OBJECT-TYPE SYNTAX PhysAddress

ACCESS read-only STATUS mandatory

DESCRIPTION

”802 address of the current root” ::= { brgState 11 }

bsDesignatedRootPriority OBJECT-TYPE SYNTAX INTEGER (1..7)

ACCESS read-only STATUS mandatory

DESCRIPTION

”Root priority of the current root (1-7)” ::= { brgState 12 }

bsDesignatedRootSequence OBJECT-TYPE SYNTAX INTEGER (0..255)

ACCESS read-only STATUS mandatory

DESCRIPTION

”Root sequence of the current root (0-255). The sequence number identifies a single instance of the root.”

::= { brgState 13 }