Applications

Setting SNMP

When SNMP is enabled, the status of this unit can be monitored from the SNMP manager of the surveillance computer. The MIB extension information (JVCNVRMIB.txt) must be registered to the SNMP manager.

1Insert a commercially available flash memory device into the serial terminal2Select [Unit Setting 2] from the main menu

2

[Main Menu List] Screen

3Select the [Enable of SNMP] check box in the [SNMP setting] section

To use TRAP, select the [Enable of TRAP] check box in the [SNMP setting] section.

Refer to [List of TRAP Supported by this Unit]

(A Page 135) for the TRAP notifications supported by this unit.

4Enter the IP address of the surveillance computer in the [SNMP manager’s address] field

5Specify the SNMP community name

Example) kanshi1

Note :

Up to 32 alphanumeric characters can be used for the community name.

TRAP signals may be missed on the receiving end depending on the communication specifications. Operate with judgement based on polling primarily and make use of TRAP only secondarily.

6Press [Copy extension MIB onto the flash memory] in the [SNMP setting] section

The MIB extension information is copied to a flash memory device.

3

4

5

6

[Unit Setting 2] Screen

7Register the MIB extension information to the SNMP manager of the surveillance computer

To register the MIB extension information to the surveillance computer, refer to the instruction manual of the SNMP manager.

8Specify the surveillance (polling) settings for the SNMP manager of the surveillance computer

For details on how to set, refer to the instruction manual of the SNMP manager.

Refer to [List of Status that can be Obtained from this Unit] (A Page 135) for the list of status that can be obtained from this unit.