Camera Control Terminal (VR-N900U)

Use connection cables according to the table below. Also make sure that you read through the instruction manual of the equipment to be connected.

Signal

Pin No.

 

 

RX+

1

 

 

RX-

2

 

 

TX-

3

 

 

TX+

4

 

 

GND

5

 

 

NC

6

 

 

NC

7

 

 

NC

8

 

 

NC

9

 

 

(D-sub 9 pin, male)

Differences when operating VR-N1600U/E and VR-N900U

The name of control buttons and operating methods may vary between VR-N1600U/E and VR-N900U. Such circumstances will be indicated using the rules below.

When name of control button is different

AIndicated accordingly using [button name of VR-N1600U/E] and (button name of VR-N900U)

Bmark is inserted at the end of the sentence

AB

Press the [16/ENTER](ZOOM IN/ENTER)button. ￿When operating method is different

The operation for the respective model is stated, and the model name is indicated at the end of the sentence.

Mounting to a Rack

Use the supplied rack mount bracket to mount this unit to the EIA rack. For the installation to the rack, consult the specialist or dealer.

1 Mount the rack mount bracket using screw (1)

Use the 4 screws (M4 x 10 mm) supplied to fasten this unit at the two sides.

2 Remove the foot screws B (4 pcs) at the bottom of the unit

Remove the foot.

3 Mount to the rack using screws C

Use the 4 screws (M5 x 11 mm) supplied to fasten this unit to the rack.

Rack Mount

Bracket

(4 Screws)

Note :

Do not place any object on this unit when it is mounted to the rack. Doing so may cause it to lose balance and drop or fall, hence resulting in injuries or damages.

When mounting more than one of this unit to the rack, make sure to mount each at a distance that is at least equivalent to one unit.

When remounting the removed foot, make sure to use same screws (M3x6 mm). Using a longer screw may cause malfunction.

21