Applications

Distribution Settings (Details) (continued)

Master/Slave Settings

This section enables you to add/delete NVR units as the slave server.

To use an NVR unit as the master server, you need to select the [Designate as Master Server] check box and register slave servers using the steps below.

Adding Slave Servers1Select [Slaves] in the [Master/Slave Setup] section

1

2Select [Add Slave] on the [Slave Administration] screen

2

3Select [Hostname]/[Port] on the [Add New Slave] screen

3

4Click the [OK] button to register the specified NVR unit as a slave server

Note :

Up to four slave servers can be registered for one NVR unit (master).

A total of 80 cameras can be managed by one master/ slave system.

The version of all NVR units in a master/slave system must be set the same.

The NVR unit operating as a master server cannot be used as a slave server for another NVR unit.

When operating as a master server, the recording display performance may drop.

Memo :

VR-N1600U/E and VR-N900U may be mixed in a master/ slave system.