Applications

Event Audio Settings (VR-N1600U/E) (continued)

Communication Settings

To make use of the event audio feature, you need to receive the communication data for triggering the generic event issued by an external device using the event audio program, and transfer it to the alert port of this unit.

You can enter the port number and alert port number (A Page 102) for receiving communication data for triggering the generic event on the [Communication setting] screen.

Note :

Do not alter the setting unless under special circumstances. Altering the setting unnecessarily may cause the system to malfunction.

1Click [Communication setting] on the [Event Audio Setting] screen

The [Communication setting] screen appears.

D

AE B

C

Item

 

 

Description

 

 

 

 

 

A Event

 

For specifying the port number for receiving

 

receive

 

communication data for triggering the generic

 

port

 

event issued by an external device.

 

 

 

 

 

B Transfer

 

For specifying the port number to transfer

 

port

 

communication data to.

 

 

 

Memo :

 

 

 

 

 

 

 

 

Specify the same port as Main

 

 

 

MenuB[Camera Record Setting]B[I/O

 

 

 

Setup]B[Details]B[Network

 

 

 

Settings]B[Alert Port]. (A Page 98)

 

 

 

 

 

 

 

 

 

C Transfer

 

For specifying the IP address to transfer the

 

IPaddress

 

generic event to. (Specify the unit itself using

 

 

 

127.0.0.1)

 

 

 

 

 

 

D OK

 

Closes the [Communication setting] screen.

 

 

 

After setting is complete, press the [Renew]

 

 

 

button on the [Event Audio Setting] screen to

 

 

 

enable the new settings.

 

 

 

 

 

E Cancel

 

Closes the [Communication setting] screen

 

 

 

without doing anything.

 

 

 

 

 

 

Memo :

To play back an audio file, register the event with [General Event Settings] of [Camera Record Setting]. (A Page 100)

External device settings:

Set the port for receiving the event (51234) as the alarm output (communication data for triggering the generic event) destination port of the external device, such as camera.

Set the IP address of this unit as the destination IP address. However, note that the IP address of this unit is not 127.0.0.1.

If the audio setting of the camera is set to the half duplex mode, you will not be able to hear audio sound from the camera during event audio transmission.

Note :

If you configure the camera event settings on the [I/O Setup] screen of [Camera Record Setting] after alarm output setting for the generic event at the camera is complete, information of the existing generic event will be overwritten, and this may cause the system to malfunction.

Do not specify the same number for the [Event receive port] and [Transfer port].

132