Description

Message

Feeder self test failed

Action

The self-test of the paper feeder failed. Perform a controlled power-down

 

sequence on the scanner. If the problem persists, call Service.

 

 

Message

Front image cal unsuccessful

Action

The imaging calibration for the front camera was unsuccessful. Clean the

 

imaging guides and retry calibration. See Chapter 5, Maintenance, “Cleaning the

 

imaging guides” for cleaning procedures.

 

 

Message

Image address field overflow

Action

One of the image address fields has exceeded its maximum configured count.

 

Check to make sure that a level change was not missed or reconfigure the

 

scanner to allow a larger value for the overflowed field.

 

 

Message

Image buffer almost full

Action

The feeder has stopped and the transport is still running because the image buffer

 

is almost full. Processing will resume when the buffer is less full.

 

 

Message

Image buffer full

Action

The image buffer overflowed.

 

One or more documents that passed through the transport were not scanned.

 

Refeed all documents for which images were not obtained.

 

 

Message

Images in buffer

Action

You tried to enable the scanner when images were still in the buffer. Not all

 

images were retrieved. Retrieve the remaining images or clear the buffer. When

 

the buffer is cleared, you may enable the scanner.

 

 

Message

Interlocks are closed

Action

Informational message. All doors are closed.

 

 

Message

Interlocks are open

Action

One of the doors is not closed or an error has not been cleared since the door(s)

 

was last opened. Check to see that all doors are closed and clear the error by

 

pressing the Return arrow (left button) on the Control Panel.

 

 

Message

Invalid IA level

Action

The image address level you tried to enter is not valid. Re-enter a correct image

 

address level. For more information about image addressing, see Kodak

 

publication, Kodak i800 Series Scanners, Image Processing Guide, A-61510.

 

 

Message

IPB needs firmware

Action

There is no firmware in an image processing board. Firmware needs to be

 

installed in all image processing boards before scanning is possible. Call Service.

 

 

Message

Lamps not ready

Action

Calibration and/or scanning was attempted before the lamps were warmed up.

 

See Chapter 3, Operator Control Panel Function’s for calibration guidelines and

 

procedures.

 

 

Message

Lamps ready for scanning

Action

Although lamps have warmed up sufficiently to allow scanning, image quality will

 

be best after the lamps have stabilized after approximately 10 minutes.

 

 

A-61169 July 2003