Using the operator panels

Insufficient collation area

Light sequence:

Continue—On

Error—On

Secondary light sequence:

Press twice quickly to see the secondary light sequence.

Continue—On

Toner Low/Replace PC Kit—On

Primary light

Secondary light

Error—On

sequence

sequence

Message:

Printer memory does not have the free space necessary to collate print job. May occur due to one of the errors listed below:

Printer memory is full.

A page is too complex to print.

Memory is insufficient to save what is in the print buffer.

Solution:

Turn printer off and back on to try printing the page again. If not successful:

Press to clear message and continue processing the job (some print data may be lost). To avoid this error in the future:

Reduce complexity of the page by reducing the amount of text or graphics.

Set Page Protect to On in the Local Printer Setup Utility (see Software and Documentation CD).

Load media

Light sequence:

Continue—On

Load / Remove Paper—On

Message:

Printer is out of media, or media did not feed properly.

Solution:

Load media into Tray 1 or priority feeder, and press to resume.

Ensure media is loaded correctly in Tray 1 or priority feeder.

Press to cancel print job.

Overview of the Lexmark E120n operator panel

36

Page 36
Image 36
Lexmark 120 manual Using the operator panels Insufficient collation area, Toner Low/Replace PC Kit-On