TOC

TOC

F-66

TROUBLESHOOTING AND REPAIR

(continued)

F-66

 

INPUT RECTIFIER REMOVAL AND REPLACEMENT

 

Return to Section

Section TOC

Return to Master

Master TOC

PROCEDURE

1.Remove input power to the POWER WAVE 355M/405M.

2.Using a 5/16” nut driver remove the case wraparound cover.

3.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.

4.Locate the input rectifier. See figure F.30.

5.Carefully remove the silicon sealant insulating the six input rectifier terminals.

6.Remove the six screws from the terminals using a flathead screwdriver. Carefully note the position of all leads and their positions upon removal. See

Figure F.31.

7.Using a 3/16”in. allen wrench remove the two mounting screws and washers from the input bridge. See Figure F.31.

8.Remove the input bridge.

NOTE: Any instructions that are packaged with the replacement board will supercede these instructions.

Return to

Return to

FIGURE F.30 – INPUT RECTIFIER LOCATION

INPUT

RECTIFIER

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

STATU

S

THERM

AL

LI

 

 

N

 

 

C

 

 

OL

 

EL

N

E

 

 

CT

 

 

RI

 

 

C

WA

 

 

RNI

 

 

NG

 

 

REMOTE

POWER

ON

OFF

POWER WAVE 355M/405M

Page 112
Image 112
Lincoln Electric 405M, 355M service manual Input Rectifier Removal and Replacement