A-13

INSTALLATION

A-13

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

I / O RECEPTACLE SPECIFICATIONS

TABLE A.2

WIRE FEEDER RECEPTACLE

PIN LEAD#

FUNCTION

A53 Communication Bus L

B54 Communication Bus H

C67A Electrode Voltage Sense

D

52

+40vdc

E

51

0vdc

TABLE A.3

VOLTAGE SENSE RECEPTACLE

 

PIN

LEAD#

FUNCTION

 

3

21A

Work Voltage Sense

 

 

TABLE A.4

 

 

RS232 RECEPTACLE

 

PIN

LEAD#

FUNCTION

2253 RS232 Receive

3254 RS232 Transmit

4

#

Pin5

5

#

Pin4

6

# #

Pin20

20

# #

Pin6

7

251

RS232 Common

DIP SWITCH SETTINGS AND

LOCATIONS

DIP switches on the P.C. Boards allow for custom con- figuration of the Power Wave. To access the DIP switch- es:

CONTROL BOARD DIP SWITCH:

switch 1 = reserved for future use switch 2 = reserved for future use switch 3 = reserved for future use switch 4 = reserved for future use switch 5 = reserved for future use switch 6 = reserved for future use switch 7 = reserved for future use switch 8* = work sense lead

switch 8*

work sense lead

 

off

work sense lead not connected

 

on

work sense lead connected

 

 

 

 

*Factory setting for Switch 8 is OFF.

FIGURE A.7

CONTROL BOARD (DIP Switch Location)

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

WARNING

1. Turn off power to the power source at the dis-

NOTE:

For PF10M Dual Boom Feeder set/up and op-

connect switch.

 

eration. The Power Wave 355M/405M control

------------------------------------------------------------------------

 

 

board dip switches must be set with 3, 4, 7 to

2. Remove the wrap around cover from the power

 

 

the “ON” position (Power Wave 355M/405M

source.

 

 

input on/off switch must be cycled to enable

 

 

 

 

any change of dip switches).

3.The control board is on the center assembly facing the case front. Locate the 8-position DIP switch and look for switch 8 of the DIP switch.

4.Using a pencil or other small object, slide the switch to the OFF position if the work sense lead is NOT connected. Conversely, slide the switch to the ON position if the work sense lead is present.

5.Replace the wrap around and screws. The PC board will “read” the switch at power up, and configure the work voltage sense lead appropriately.

O

N

1 2 3 4 5 6 7 8

POWER WAVE 355M/405M

Page 21
Image 21
Lincoln Electric 355M, 405M service manual DIP Switch Settings Locations, Control Board DIP Switch