to Master TOC

F-16TROUBLESHOOTING AND REPAIRF-16

MAIN SWITCH BOARD TEST (continued)

FIGURE F.2 MAIN SWITCH BOARD LEAD LOCATIONS

Return

Return

207

- +

202

J22

- +

Return to Section TOC

Return to Master TOC

201

208

J21

- +

204

205

- +

209

J20

to Master TOC

203

206

TEST PROCEDURE

Return

Return to Master TOC

1.Remove input power to the POWER WAVE 355M/405M.

2.Using a 5/16” nut driver, remove the case wraparound.

3.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.

4.Using a 7/16” wrench locate, label and remove leads 201, 202, 203, 204, 205, 206, 207 and 208 from the switch board. Note lead and washer placement for reassembly. Clear leads.

5.Using the Analog ohmmeter, perform the resis- tance tests detailed in Table F.1. Refer to fig- ure F.2 for test point locations. Note: Test using an Analog ohmmeter on the Rx1 range. Make sure the test probes are making electri- cal contact with the conductor surfaces on the PC board.

Return

POWER WAVE 355M/405M

Page 62
Image 62
Lincoln Electric 405M, 355M service manual 16TROUBLESHOOTING and REPAIRF-16, Test Procedure