TECHNICAL SPECIFICATIONS -
POWERWAVE 405
INPUT ACVOLTAGE & DC OUTPUT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Product Ordering Input AC Rated DC Output Output Weight Dimensions
Name Information Voltage Amps/Volts/DutyCycle Range withCord HxWxD
(continuous)
335500AA // 3344VV // 6600%% 1144..77xx1122..55xx
PPoowweerr220000--220088 //33 PPhhaassee 2277..88**
WWaavveeKK 22115522--22 222200--224400// 332200AA // 3333VV // 6600%% AAMMPPSS8866..55llbbss((337733xx331188xx
440055338800--441155//11 PPhhaassee 55--442255((3377..44 kkgg)) 770066**))mmmm
33//5500//6600
6
60
0/
/5
50
0
H
Hz
z
227755AA // 3311VV //110000%%
11 PPhhaassee
330000AA // 3322VV // 110000%%** IInncclluuddeess
33 PPhhaassee hhaannddlleess
* Overall Length Including Handle, 21.6” (549mm) without ha ndle.
Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE CURRENT LENGTH UP 61m (200 FT) 61-76m (200-250 FT)
100% 275 1/0 1/0
60% 350 1/0 2/0
POWER WAVE 405 INPUT CURRENT
2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
1. Not rated is indicated by 4-x's in the box on the rating plate
Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz Output Recommended
Voltage Phases 300Amps@ 350Amps@ Line Cord Size Fuse Size Notes
32Volts(100%) 34Volts(60%) Size mm2
200 3 41 48 16 80A Note 2
220 3 37 48 16 80A Note 2
380 3 23 28 10 50A
400 3 22 27 10 50A
415 3 22 26 10 50A
Voltage Phases 275Amps@ 320Amps@ Line Cord Fuse Size Notes
31Volts(100%) 33Volts(60%) Size mm2
200 1 Not Recommended Not Recommended --- ----- Note 1
220 1 64 82 20 125A Note 2
380 1 44 55 16 80A Note 2
400 1 40 50 10 80A
415 1 38 48 10 80A