OPERATION |
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
POWER WAVE 355M/405M – Semi-Automatic Operation
Semi Automatic Power Waves can only be used with Arclink compatible Power Feed
All welding programs and procedures are selected through the Power Feed
REQUIRED EQUIPMENT
Any Arclink compatible
LIMITATIONS
•Only Arclink compatible Power Feed
•POWER WAVE 355M/405M Output Limitations
The POWER WAVE 355M/405M will support maxi- mum average output current of 350 Amps @ 60% duty cycle.
DUTY CYCLE AND TIME PERIOD
The duty cycle is based upon a ten minute period. A 60% duty cycle represents 6 minutes of welding and 4 minutes of idling in a ten minute period.
CASE FRONT CONTROLS
All operator controls and adjustments are located on the case front of the Power Wave. (See Figure B.1)
1.POWER SWITCH: Controls input power to the Power Wave.
2.STATUS LIGHT: A two color light that indicates sys- tem errors. Normal operation is a steady green light. Error conditions are indicated, per table B.1.
NOTE: The POWER WAVE 355M/405M status light will flash green, and sometimes red and green, for up to one minute when the machine is first turned on. This is a normal situation as the machine goes through a self test at power up.
| TABLE B.1 |
|
|
Light | Meaning |
Condition |
|
Steady Green | System OK. Power source communicating |
| normally with wire feeder and its components |
| if other feeder & components show they are |
| powered up. |
|
|
Blinking | Occurs during a reset, and indicates the |
Green | POWER WAVE 355M/405M is mapping |
| (identifying) each component in the system. |
| Normal for first |
| turned on, or if the system configuration is |
| changed during operation |
|
|
Alternating | |
Green and | Status light is flashing any combination of red |
Red | and green, errors are present in the POWER |
| WAVE 355M/405M. Read the error code |
| before the machine is turned off. |
| Error Code interpretation through the Status |
| light is detailed in the LED Status Chart. |
| Individual code digits are flashed in red with |
| a long pause between digits. If more than |
| one code is present, the codes will be sepa- |
| rated by a green light. |
| To clear the error, turn power source off, and |
| back on to reset. |
|
|
Steady Red | Non recoverable hardware fault. Generally |
| indicates nothing is connected to the |
| POWER WAVE 355M/405M wire feeder |
| receptacle. See Trouble Shooting Section. |
|
|
Blinking Red | Not applicable. |
|
|
3.HIGH TEMPERATURE LIGHT (thermal overload): A yellow light that comes on when an over temper- ature situation occurs. Output is disabled and the fan continues to run, until the machine cools down. When cool, the light goes out and output is enabled.
4.CB1 WIRE FEEDER CIRCUIT BREAKER: Protects 40 volt DC wire feeder power supply.
Return
POWER WAVE 355M/405M