Return to Section TOC
Return to Master TOC
CONTROL BOARD REMOVAL AND REPLACEMENT (continued)
FIGURE F.17 - CONTROL BOARD LOCATION
Return to Section TOC
Return to Master TOC
STATU
S
THERM
AL
LINC
ELOLN
ECTRIC
WARNING
REMOTE
POWER
ON
OFF
Control Board
PROCEDURE
1.Remove input power to the POWER WAVE 355M/405M.
2.Using a 5/16” nut driver remove the case wrap- around cover.
3.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.
4.Locate the control board behind the front panel of the machine. See Figure F.17.
5.Using a 5/16” nut driver remove the two screws from the bottom of the front of the machine. See Figure F.18.
Return to Section TOC
Return to Master TOC
FIGURE F.18 CASE FRONT SCREW REMOVAL
STATUSTHERMAL
Return to Section TOC
Return to Master TOC
Phillips Head
Screws
_ +
5/16"
Mounting Screws
POWER WAVE 355M/405M
Phillips Head
Screws