TOC
TOC
TROUBLESHOOTING AND REPAIR | |||
USING THE STATUS LED TO | bleshooting charts for both machine and weld perfor- | ||
TROUBLESHOOT SYSTEM PROBLEMS | mance. |
| |
|
| power source Status LED, and some basic trou- |
|
Return to Section
Return to Master
The Power Wave / Power Feed are best diagnosed as a system. Each component (power source, user interface, and feed head) has a status light, and when a problem occurs it is important to note the condition of each. In addition, errors displayed on the user interface in most cases indicate only that a problem exists in the power source, not what the problem may be. Therefore, prior to cycling power to the sys- tem, check the power source status light for error sequences as noted below. This is especially important if the user interface displays “Err 006” or “Err 100”.
Included in this section is information about the
The STATUS LIGHT is a two color light that indicates system errors. Normal operation is a steady green light. Error conditions are indicated in the following chart.
NOTE: The POWER WAVE 355M/405M status light will flash green, and sometimes red and green, for up to one minute when the machine is first turned on. This is a normal situation as the machine goes through a self test at power up.
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
LIGHT CONDITION |
| INDICATION |
Status LED is solid green (no blinking) | 1. System OK. Power source communicating nor- | |
|
| mally with wire feeder and its components. |
|
|
|
Status LED is blinking green | 2. | Occurs during a reset, and indicates the |
|
| POWER WAVE 355M/405M is mapping (identi- |
|
| fying) each component in the system. Normal |
|
| for first |
|
| or if the system configuration is changed during |
|
| operation. |
|
|
|
Status LED is blinking red and green | 3. | |
|
| light is flashing any combination of red and |
|
| green, errors are present in the POWER WAVE |
|
| 355M/405M. Read the error code before the |
|
| machine is turned off. |
|
| Error Code interpretation through the Status |
|
| light is detailed in the Service Manual. |
|
| Individual code digits are flashed in red with a |
|
| long pause between digits. The codes will be |
|
| separated by a green light. There may be more |
|
| than one error code indicated. |
|
| To clear the error, turn power source off, and |
|
| back on to reset. |
|
|
|
Status LED is solid red (no blinking). |
| |
|
| cates nothing is connected to the POWER |
|
| WAVE 355M/405M wire feeder receptacle. See |
|
| Trouble Shooting Section. |
|
|
|
Status LED is blinking red. |
| Not applicable |