Return to Section TOC
Return to Master TOC
OUTPUT RECTIFIER MODULES TEST (continued)
Figure F.8 Terminal Probes
Return to Section TOC
Return to Master TOC
_
PROBE -
+
+
PR
O
B
E
Return to Section TOC
Return to Master TOC
5.If 200 ohms is measured then the output diodes are not “shorted”.
NOTE: There is a 250 ohm resistor across the welding output terminals. See Wiring
Diagram
6.If less than 200 ohms is measured, one or more diodes or the snubber board may be faulty.
7.Perform the Filter Capacitor Discharge Procedure detailed in the maintenance sec- tion.
8.Locate the output diode modules and snub- ber board. See Figure F.9.
9.Test all output diode modules individually. Test for open diodes also.
NOTE: This may require the disassembly of the leads and the snubber board from the diode modules. Refer to the Output
Rectifier Modules Removal and Replacement Procedure for detailed instructions.
Return to Section TOC
Return to Master TOC