F-25

TROUBLESHOOTING AND REPAIR

F-25

 

POWER BOARD TEST (CONTINUED)

 

 

TABLE F.3 – POWER BOARD VOLTAGE CHECKS

 

CHECK POINT

TEST

CONNECTOR

LEAD NO. OR

NORMAL

LOCATION

DESCRIPTION

PLUG PIN NO.

IDENTITY

ACCEPTABLE

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

READING

POWER BOARD

CHECK 40 VDC

 

2 (+)

 

 

38 – 42 VDC

CONNECTOR

INPUT FROM

475

1 (-)

477

477 (+)

 

PLUG J41

DC BUS BOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

475 (-)

 

POWER BOARD

CHECK +15

 

1 (+)

 

 

+15 VDC

CONNECTOR

VDC SUPPLY FROM

412

5 (-)

 

412 (+)

 

PLUG J42

POWER BOARD

 

 

 

 

 

 

 

 

410

 

410 (-)

 

 

 

 

 

 

 

POWER BOARD

CHECK +5 VDC

 

3 (+)

 

 

+5 VDC

CONNECTOR

SUPPLY FROM

 

5 (-)

408

408 (+)

 

PLUG J42

POWER BOARD

 

 

 

 

 

 

 

 

 

 

410 (-)

 

 

 

 

410

 

 

 

POWER BOARD

CHECK -15 VDC

411

2 (+)

 

 

-15 VDC

CONNECTOR

SUPPLY FROM

 

5 (-)

 

411 (+)

 

PLUG J42

POWER BOARD

 

 

 

 

 

 

 

 

 

 

410 (-)

 

 

 

410

 

 

 

 

POWER BOARD

CHECK +5 VDC

 

5 (+)

 

1104 (+)

+5 VDC

CONNECTOR

ARCLINK SUPPLY

 

10 (-)

1104

 

PLUG J43

FROM POWER BOARD

 

 

 

1103 (-)

 

 

 

 

 

 

 

 

 

 

 

1103

 

 

POWER BOARD

CHECK +5 VDC

 

4 (+)

 

406 (+)

+5 VDC

CONNECTOR

“RS-232” SUPPLY

 

9 (-)

406

 

PLUG J43

FROM POWER BOARD

 

 

 

405 (-)

 

 

 

 

 

 

 

 

 

405

 

 

 

 

 

 

3 (+)

 

403 (+)

+5 VDC

POWER BOARD

CHECK +5 VDC

403

12 (-)

 

 

CONNECTOR

SPI SUPPLY FROM

 

 

 

401 (-)

 

PLUG J43

POWER BOARD

 

 

 

 

 

 

 

 

401

 

 

POWER WAVE 355M/405M

Page 71
Image 71
Lincoln Electric 355M, 405M service manual Power Board Test