TROUBLESHOOTING AND REPAIR

F-8

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

 

 

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

FUNCTION PROBLEMS

1. Perform the Auxiliary

 

 

 

 

 

 

 

Auxiliary receptacle is “dead” no

1.

Circuit breaker CB1 (on case

 

 

auxiliary voltage.

 

 

front) may have opened. Reset.

Transformer Test.

 

 

 

 

2.

Circuit breaker CB3 (in recon-

 

 

 

 

 

 

nect area) may have opened.

 

 

 

 

 

 

Reset.

 

 

 

 

 

 

3.

On PW 405 models, the circuit

 

 

 

 

 

 

breaker

CB4 protects the

 

 

 

 

 

 

220VAC

receptacle. Reset if

 

 

 

 

 

 

tripped.

 

 

 

 

 

 

 

 

A fault or error code is displayed.

1. See Fault Code Explanations.

1. See Fault Code Explanations.

General degradation of the weld 1.

Check for feeding

problems,

1.

Perform the Voltage and

performance.

bad

connections,

excessive

 

Current Calibration Procedure

 

loops in cabling, etc.

 

 

using the Power Wave software

 

 

 

 

 

program.

2.

Verify weld mode is correct for

 

 

 

processes.

 

2.

Perform the Current

 

 

 

 

 

Transducer Test.

3.

The power source may require

 

 

 

calibration.

 

2.

Perform the Output Diode

 

 

 

 

 

Module Test.

4.

Check the actual current dis-

 

 

 

played on the Power Feed 10

5.

The control board may be

 

vs. actual current measured via

 

faulty.

 

external meter.

 

 

 

5.

Check the actual voltage dis-

 

 

 

played on the Power Feed 10

 

 

 

vs. actual voltage measured via

 

 

 

external meter.

 

 

 

6.

Check the actual WFS displayed

 

 

 

on the Power Feed 10 vs. actual

 

 

 

WFS

measured via external

 

 

 

meter.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

Page 54
Image 54
Lincoln Electric 405M, 355M service manual Transformer Test, Wfs