CURRENT TRANSDUCER TEST (continued)

FIGURE F.12 Metal Plate Removal & Plug J8 Location

Return to Section TOC

Return to Master TOC

STATU

S

THERM

AL

LINECOLN

LECTRIC

WARNING

REMOTE

POWER

ON

OFF

Plug J8

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Remove input power to the POWER WAVE 355M/405M.

2.Using the 5/16” nut driver, remove the case wraparound cover.

3.Perform the Input Capacitor Discharge

Procedure.

4.Locate plug J8 on the control board. Do not remove the plug from the P.C. Board.

5.Apply the correct input power to the POWER WAVE 355M/405M.

6.Check for the correct DC supply voltages to the current transducer at plug J8. See Figure F.12.

A.Pin 2 (lead 802+) to pin 6 (lead 806-) should read +15 VDC.

B.Pin 4 (lead 804+) to pin 6 (lead 806-) should read -15 VDC.

7.If either of the supply voltages are low or miss- ing, the control board may be faulty.

Return to Section TOC

Return to Master TOC

FIGURE F.13. Plug J8 Viewed From Lead Side of Plug

802 804

801

Plug J8

806

POWER WAVE 355M/405M