DEFINITY® Enterprise Communications Server Release 7 | Issue 4 |
Console Operations | June 1999 |
4 Using the Features |
|
Using Features for Internal Use | 62 |
|
|
Clocked Manual Override
This option lets you specify the day and time to override the scheduled
In the following procedure, a number from 1 through 8 specifies the desired routing plan; a number from 1 through 7 specifies the day (1 is for Sunday and 77 is for Saturday). The time is specified in military hours (0000 for 1:00 a.m. and 2359 for midnight).
To activate Clocked Manual Override:
NOTE:
The Clocked Override lamp is lit if this option is already active.
1.Press the Clocked Override button.
■The Clocked Override lamp lights.
■First line of display shows:
ENTER ACTIVATE ROUTE PLAN, DAY & TIME
2.Use the
Press the 1 through 8 button (to specify the routing plan) and the 1 through 7 button (to specify the day) 0000 through 2359 (to specify the hour).
■The Clocked Override lamp remains steadily lighted.
■Display shows:
ROUTE PLAN: x FOR: yyy
(Where x is the routing plan number, yyy is the
NOTE:
If you enter any invalid information, the Clocked Manual Override attempt is denied; the display returns to the Normal mode. You must repeat step 1 to try again.
To enter a deactivate date:
1.Press the Clocked Override to confirm activation input data and to enter deactivation time.
■The Clocked Override lamp remains steadily lighted.
■Display shows: