INSTALLATION KIT - see Figure 2-2

 

 

 

 

 

 

SECTION 2 - INSTALLATION

II.

INSTALLATION KIT - see Figure 2-2

 

Fig. 2-2 - Installation Kit

NOTE: One Installation Kit is required for each oven cavity.

1

5

2

 

 

 

 

Item

Qty.

Part No.

Description

4

 

3

1

1

35900-0148

Conveyor Rear Stop

 

 

 

 

2

1

35000-1103

Conveyor End Stop

 

 

 

3

1

46450

Owner's Operating & Installation Manual

 

 

 

4

1

1002040

Authorized Service Agency Listing

 

 

 

ADDITIONAL COMPONENTS FOR GAS OVENS:

 

 

 

5

1

33120-0053

Gas Pipe Nipple

 

 

 

ENGLISH

III. VENTILATION SYSTEM

IMPORTANT

Where national or local codes require the installation of fire suppression equipment or other supplementary equipment, DO NOT mount the equipment directly to the oven.

MOUNTING SUCH EQUIPMENT ON THE OVEN MAY:

VOID AGENCY CERTIFICATIONS

RESTRICT SERVICE ACCESS

LEAD TO INCREASED SERVICE EXPENSES FOR THE OWNER

A.Requirements

CAUTION

Gas oven installations REQUIRE a mechanically driven ventilation system with electrical exhaust air sensing control.

A mechanically driven ventilation system is STRONGLY RECOMMENDED for electric oven installations.

PROPER VENTILATION OF THE OVEN IS THE RESPONSIBILITY OF THE OWNER.
B.Recommendations

NOTE THAT THE HOOD DIMENSIONS SHOWN IN FIGURE 2- 3 ARE RECOMMENDATIONS ONLY. LOCAL, NATIONAL, AND INTERNATIONAL CODES MUST BE FOLLOWED WHEN INSTALLING THE VENTILATION SYSTEM. ANY APPLICABLE

CODES SUPERSEDE THE RECOMMENDATIONS SHOWN IN THIS MANUAL.

The rate of air flow exhausted through the ventilation system may vary depending on the oven configuration and hood design. Consult the hood manufacturer or ventilation engineer for these specifications.

To avoid a negative pressure condition in the kitchen area, return air must be brought back to replenish the air that was exhausted. A negative pressure in the kitchen can cause heat- related problems to the oven components as if there were no ventilation at all. The best method of supplying return air is through the heating, ventilation and air conditioning (HVAC) system. Through the HVAC system, the air can be temperature- controlled for summer and winter. Return air can also be brought in directly from outside the building, but detrimental effects can result from extreme seasonal hot and cold temperatures from the outdoors.

NOTE: Return air from the mechanically driven system must not blow at the opening of the baking chamber. Poor oven baking performance will result.

C.Other ventilation concerns

Special locations, conditions, or problems may require the services of a ventilation engineer or specialist.

Inadequate ventilation can inhibit oven performance.

It is recommended that the ventilation system and duct work be checked at prevailing intervals as specified by the hood manufacturer and/or HVAC engineer or specialist.

18” (458mm)

Fig. 2-3 - Ventilation System

 

 

 

 

minimum

 

 

 

(Typical - both

2” (51mm)

8” (203mm)

3” (76mm)

ends of oven)

minimum

minimum

minimum

7