Write Access:

Timed Access Protected. Cannot be written by the application software if

 

set to 0000B by the serial loader. If a 0000B is written via the serial loader

 

and the security lock is set, the Partition will become 1111B. The same will

 

occur if write access is available and application software writes a 0000B. In

 

addition, these bits will be set to 1111B if security lock is cleared.

MCON.3:

RG1

 

One of two bits that determine the range of program space. RG0 is located

 

in the RPCTL register.

Initialization:

Unaffected by watchdog, external, or power±up resets. Set to 1 on a No VLI

 

reset or a clearing of the security lock.

Read Access:

Can be read at any time.

Write Access:

Cannot be modified by the application software. Can only be written via the

 

Bootstrap Loader.

MCON.2:

PES

 

Peripheral Enable Select. When this bit is set, the data space is controlled

 

by PE1±PE4. Peripherals are memory±mapped in 16K blocks, and are

 

accessed by MOVX instructions on the Byte±wide bus.

Initialization:

Cleared by all resets.

Read Access:

Can be read at any time.

Write Access:

Can be written at any time.

MCON.1:

PM

 

Partition Mode. When PM=0, a partitionable, continuous memory map is

 

invoked. When PM=1, one of four fixed allocations is used.

Initialization:

Unaffected by watchdog, external, or power±up resets. Cleared on a No VLI

 

reset.

Read Access:

Can be read at any time.

Write Access:

Cannot be modified by the application software. Can only be modified via

 

the Boostrap Loader.

MCON.0:

SL

ªSecurity Lockº:

Indicates that the security lock is set when SL=1.

Initialization:

Cleared to a 0 on a no VLI power on reset.

Read Access:

Read normally any time.

Write Access:

Can only be modified by the Lock and Unlock commands of the Bootstrap

 

loader. This bit cannot be modified by the application software or by the

 

Bootstrap loader Write command.