3.Turn the JOG dial to move the cursor ( ) to NORMAL REC SETTING then turn the SHUTTLE ring to the right.

The <NORMAL REC SETTING> menu appears.

<NORMAL

REC

SETTING>￿

@IMAGE QUALITY

HIGH￿

MAX REC FIELDS

12.5F￿

SELECT REC

MODE

(A)￿

DEFINE GROUP SETTING

4.Check that the cursor is next to the IMAGE QUALITY and turn the SHUTTLE ring to the right.

The sub-item of IMAGE QUALITY will start flashing.

<NORMAL

REC

SETTING>￿

@IMAGE QUALITY

HIGH￿

MAX REC FIELDS

12.5F￿

SELECT REC

MODE

(A)￿

DEFINE GROUP SETTING

5.Display STANDARD by turning the JOG dial then turn the SHUTTLE ring to the right.

The flashing will stop. Now the setting has been completed.

<NORMAL

REC

SETTING>￿

@IMAGE QUALITY

STANDARD￿

MAX REC FIELDS

12.5F￿

SELECT REC

MODE

(A)￿

DEFINE GROUP SETTING

By turning the JOG dial, the im- age quality setting will be changed as below :

HIGH SUPERIOR BASIC

MEDIUM STANDARD

Setting the maximum recording fields

Example: Setting the maximum recording fields to “6.25F” (the default setting is “12.5F”).

1.After step 5 of IMAGE QUALITY setting procedures above, turn the JOG dial and move the cursor to “MAX REC FIELDS”.

<NORMAL

REC SETTING>￿

IMAGE QUALITY

STANDARD￿

@MAX REC FIELDS

12.5F￿

SELECT REC MODE

(A)￿

DEFINE GROUP SETTING

2. Turn the SHUTTLE ring to the right to flash the sub-item.

<NORMAL

REC SETTING>￿

IMAGE QUALITY

STANDARD￿

@MAX REC FIELDS

12.5F￿

SELECT REC MODE

(A)￿

DEFINE GROUP SETTING

3.Turn the JOG dial to display “6.25F” then turn the SHUTTLE ring to the right.

The “6.25F” is now selected.

<NORMAL

REC SETTING>￿

IMAGE QUALITY

STANDARD￿

@MAX REC FIELDS

6.25F￿

SELECT REC MODE

(A)￿

DEFINE GROUP SETTING

By turning the JOG dial, the maxi-

mum recording fields setting will be changed as below:

25F

12.5F

 

8.33F

6.25F

 

 

 

1F

2.5F

4.17F

5F

 

 

 

 

The underlined items cannot be selected when the MOTION DETECTION setting is active.

When MOTION DETECTION setting in the INI- TIAL SET UP menu is turned ON, the MAX REC

FIELDS for each time setting will be automatically altered as follows. These settings will not automati- cally revert to their former values even if MOTION DETECTION is turned OFF.

Case of <NORMAL REC SETTING> menu and <A- REC/M-DET SETTING> menu.

“25F” } “12.5F”, “8.33F” } “6.25F” , “5F” } “4.17F”

Case of “MODE” in the <TIMER PROGRAM> menu. “25” } “12.5”, “8.33” } “6.25” , “5” } “4.17”

The setting you are making here is only for the nor- mal recording, NOT for the timer recording or alarm recording. You need to make the timer recording set- tings on the <TIMER PROGRAM> menu. And you need to make the alarm recording setting on the <A-REC/ M-DET SETTING> menu. For details please refer to “Various recording settings” on page 35.

The settings made for IMAGE QUALITY and MAX REC FIELDS are shared with A, B, and C of SE-

LECT REC MODE.

Press the SET UP button to exit settings.

4.Check the estimated recording time.

After setting the image quality the <ESTD TIME> will be displayed. By changing recording settings, <ESTD TIME> will change its length of time (Alarm recording setting does not affect this setting).

<NORMAL REC SETTING>￿

IMAGE QUALITY

STANDARD￿

@MAX REC FIELDS

6.25F￿

SELECT REC MODE

(A)￿

DEFINE GROUP SETTING￿

￿

 

￿

 

￿

 

￿

 

￿

1D12H11M

<ESTD TIME>

The available recording time will be changed de- pending on the setting of the image quality and the

max recording fields. This estimated recording time display will include all HDD including external devices. For available recording time, please refer to “Record- ing time table” on pages 81.

Selecting the recording mode of the cameras There are 3 types of the recording mode : A, B and C. This setting is to choose the SELECT REC MODE on the <NORMAL REC SETTING> menu.

Example: Choose SELECT REC MODE (B) (the default setting is (A)).

1.After step 3 of MAX REC FIELDS setting procedures above, turn the JOG dial and move the cursor to “SELECT REC MODE”.

<NORMAL

REC SETTING>￿

IMAGE QUALITY

STANDARD￿

MAX REC FIELDS

6.25F￿

@SELECT

REC MODE

(A)￿

DEFINE

GROUP SETTING

ENGLISH

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Basic Operations

13

Page 13
Image 13
Mitsubishi Electronics DX-TL1600EM Setting the maximum recording fields, Press the SET UP button to exit settings