3) Settings for TIMER PROGRAM are made as follows.

Designate Monday to Friday as the days of operation (SPECIAL DW). Then, in Program #1, set the action (MODE)

to “A– 1” for 08:00 to 15:00 on the designated days(SPL).

In Program #2, set the action to “B– 1” for 15:00 to 20:00 on the designated days.

In Program #3, set the action to “B– 1” for 08:00 to 17:00 on Saturday.

In Program #4, set the action to “B– 1” for 08:00 to 17:00 on Sunday.

In Program #5, set the action to “EJECT” for Sunday’s start- time of 00:00 to end-time of 05:00.

Upon completing the above settings, press the unit’s TIMER REC button to initiate Timer operation.

Operation example 4

This is an operation example of a Timer setting that com- bines NORMAL REC with Alarm Recording using MOTION DETECTION.

System configuration

Settings are entered so that the backups are created every Monday morning between 00:00 and 05:00. To facilitate the exchange of the storage medium after the backup has been completed, MODE is set to “EJECT”.

Cameras in SELECT REC MODE (A) are set to operate from 08:00 to 15:00 on Monday through Friday. Set the unit on POWER from 15:00 to 08:00 the next morning.

Cameras in SELECT REC MODE (B) are set to operate from 08:00 to next day 08:00 on Saturday and Sunday. The overall schedule is as shown in the following chart.

00 : 00 05 : 00 Monday Archive

replace archive medium

 

 

08 : 00

15 : 00

 

Monday to Friday

 

 

 

 

 

 

SELECT REC MODE (A)

24 : 00

00 : 00

08 : 00

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

Saturday and Sunday

08 : 00

24 : 00

 

 

 

 

 

 

 

 

 

 

 

 

SELECT REC MODE (B)

 

00 : 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT REC MODE (B)

 

 

 

 

Settings

1)Enter the same settings for the camera operation set- ting A as those for operation example 3 in the following: the CAMERA TITLE setting (on the <MPX DISPLAY> menu), DEFINE GROUP SETTING (on the <NORMAL REC SET- TING> menu), and recording conditions. Set the power set- ting that uses MOTION DETECTION as follows.

Set IMAGE QUALITY to “HIGH”.

Set MAX REC FIELDS to “1F”.

Set A-REC DURATION to “5M”.

Set RECORD ALARM to “ALL”.

Set PRE A-REC to “MEDIUM”.

On the <DEFINE ALARM GROUP> menu, set the cameras Q,W,E,I,O,} and w.

<DEFINE ALARM GROUP>￿

CH PRI FILD

CH PRI FILD￿

@Q

2

0.11

O

1

0.22￿

W

1

0.22

P

-

 

E

1

0.22

{

-

0.22￿

R

-

 

}

1

T

-

 

q

-

￿

Y

-

 

w

1

0.22￿

U

-

0.11

e

-

￿

I

2

r

-

￿

 

 

 

 

 

2)Settings for MOTION DETECTION SETTING are made as follows.

To make the M-DET SETTING, first turn the MOTION DETECTION setting “ON” in the <INITIAL SET UP> menu.

Using SELECTION CAMERA NO., set each of the following camera numbers Q, W, E, I, O, } and w as follows.

Set CH.MOTION DETECTION to “ON”.

Set SET DETECTION MASK, SENSITIVITY, MOTION THRESHOLD TEST MODE.

<MOTION>￿

 

￿

@SELECTION CAMERA NO. 1

￿

ON ￿

CH.MOTION DETECTION

SET DETECTION MASK￿

HIGH￿

 

SENSITIVITY

￿

MOTION THRESHOLD

5

TEST MODE

OFF

 

3)Settings for TIMER PROGRAM are made as follows.

Select “P1” for the setting “SELECTED PATTERN” in the <TIMER PROGRAM> menu and select “ON” for the setting “REC MODE (POWER)” in the <M-DET APPLICATION> menu.

<TIMER PROGRAM>￿

P1

SELECTED PATTERN￿

DEFINE P1￿

 

DEFINE P2￿

 

DEFINE P3￿

 

￿

 

<M-DET APPLICATION>￿

OFF￿

REC MODE (A)

REC MODE (B)

OFF￿

REC MODE (C)

OFF￿

@REC MODE (POWER)

ON￿

￿

 

Designate Monday to Friday as the days of operation (SPECIAL DW). Then, in Program #1, set the action (MODE)

to “A– 1” for 08:00 to 15:00 on the designated days(SPL).

In Program #2, set the action to “POWER” for 15:00 to 08:00 the next morning.

In Program #3, set the action to “POWER” for 08:00 to 08:00 the next morning.

In Program #4, set the action to “POWER” for 08:00 to 08:00 the next morning.

In Program #5, set the action to “EJECT” for Sunday’s start- time of 00:00 to end-time of 05:00.

Upon completing the above settings, press the unit’s TIMER REC button to initiate Timer operation.

ENGLISH

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operations

49

Page 49
Image 49
Mitsubishi Electronics DX-TL1600EM operation manual Settings for Timer Program are made as follows