Please note that in the A-REC DURATION set- ting, MAN cannot be selected when the MOTION DE-

TECTION setting in the <INITIAL SET UP> menu is “ON”.

13.Turn the SHUTTLE ring to the left or press the SET UP button.

INFORMATION

Please refer to “Alarm Recording op- eration” on page 53 for details of the alarm recording.

Camera Alarm Rec setting

This is the setting for the camera to start recording when ALARM IN terminal is grounded (alarm recording signal is input). This setting is only effective during alarm recording. After alarm recording, operations return to their prior settings.

Example: Setting the RECORD ALARM to “ALL” (the de- fault setting is “SEP”).

1.Press the SET UP button to display the <MENU SETTING> menu.

2.Turn the JOG dial to move the cursor to A-REC/M-DET SETTING then turn the SHUTTLE ring to the right.

The <A-REC/M-DET SETTING> menu will appear.

3.Turn the JOG dial to move the cursor to RECORD ALARM then turn the SHUTTLE ring to the right to fix setting.

The sub-item will start flashing.

4.Turn the JOG dial to display “ALL”, and turn the SHUTTLE ring to the right to fix setting.

The sub-item will stop flashing.

A-REC DURATION

15S￿

@RECORD ALARM

ALL￿

PRE A-REC

OFF

By turning the JOG dial, the sub - item of RECORD ALARM will be changed as follows:

SEP ALL

“SEP”: The alarm recording will start only with the camera which received the alarm signal. If several cameras received alarm input at once, all of those cameras will start alarm recording.

“ALL”: The alarm recording will start with all cameras set to be operated on the <DEFINE ALARM GROUP> menu when ALARM IN terminal is grounded.

1.Make settings for IMAGE QUALITY , MAX REC FIELDS , DEFINE GROUP SETTING, A-REC DURATION and RECORD ALARM as shown on page 35 - 37 .

A-REC DURATION

5M￿

@RECORD ALARM

ALL￿

PRE A-REC

OFF

2.Turn the JOG dial to move the cursor to PRE A-REC and turn the SHUTTLE ring to the right to flash the sub-item.

A-REC DURATION

5M￿

RECORD ALARM

ALL￿

@PRE A-REC

OFF

3.Turn the JOG dial to flash LONG, and turn the SHUTTLE ring to the right. The unit will be in stand-by mode for the

Pre-alarm recording.

PRE ALARM REC indicator on the front of the unit will start illuminating.

A-REC DURATION

5M￿

RECORD ALARM

ALL￿

@PRE A-REC

LONG

By turning the JOG dial, the sub- item of PRE A-REC will be changed as follows:

OFFSHORT

LONG MEDIUM

4.Ground the ALARM IN terminal.

The unit will start alarm recording.

The duration of recording before the ALARM IN ter- minal is triggered depends on the MAX REC FIELDS,

IMAGE QUALITY, and PRE A-REC settings. Please refer to “Pre-alarm Recording” on page 54 for details.

Setting cannot be altered in either the NORMAL REC SETTING menu or the A-REC/M-DET SET-

TING menu when the PRE A-REC menu is set to SHORT, MEDIUM, or LONG. In addition, the SE- LECT REC MODE (in the <NORMAL REC SET- TING> menu) will display A-REC.

INFORMATION

To activate pre-alarm recording on Timer programmes, please refer to “Pre-alarm Re-

cording” on page 54.

Following the end of Pre-alarm recording, the regular value of the Alarm Recording settings returns to the value set in the IMAGE QUALITY, MAX REC FIELDS, DEFINE GROUP SETTING, and A-REC DURATION settings.

Alarm input

(ALARM IN signal)

ENGLISH

5.Turn the SHUTTLE ring to the left or press the SET UP button.

When the RECORD ALARM setting is set to “SEP”, the “PRI” setting on the <DEFINE GROUP SETTING>

menu at this time can only be either “ 1 ” or “ - ”, and then the “FILD” will not be appear on screen.

Pre-alarm recording setting

During alarm recording, it is possible to record the infor- mation before the ALARM IN terminal is activated.

Example: Set the PRE A-REC to “LONG” (the default set- ting is “OFF”).

Recording

Mode

Effective recording setting

Effective recording

CAMERA CH setting

Pre - alarm recording

LONG/MEDIUM/SHORT of

PRE A-REC

IMAGE QUALITY/

MAX REC FIELDS of A-REC

All the CAMERA CH

set in PRIORITY settings 1 – 5 of the DEFINE ALARM GROUP setting.

Alarm recording

IMAGE QUALITY/

MAX REC FIELDS/

A-REC DURATION

When RECORD ALARM setting is SEP, only the CAMERA CH receiving an Alarm Recording signal.

When RECORD ALARM setting is ALL, all the CAMERA CH specified in the DEFINE GROUP SETTING setting.

When you wish to use the ALARM IN signal to activate Alarm Recording,

CAMERA CH of the cameras to be used must be set to something other than "—".

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operations

37

Page 37
Image 37
Mitsubishi Electronics DX-TL1600EM Tection setting in the Initial SET UP menu is on, Camera Alarm Rec setting, Cording on